Fixed Systems
|
|
COMBI C689
(Addressable/Direct Gas Monitoring System)
|
|
|
 |
Up
to 64 addressable sensors |
 |
1-16 direct 4~20mA sensors - 2/3 wire |
 |
Either
or both types of sensors |
 |
Single
4 core sensor network (addressable) |
 |
On
screen text description of sensor locations |
 |
3
alarm levels |
 |
Event - data logging - internal 99 event |
 |
Low
cost installation |
 |
Repeater
panel - option |
 |
64
Additional relays - option |
 |
Continuous data logging via PC - option |
 |
Addressable relay board - option |
 |
One man calibration utilising peak readings |
 |
Automatic safety check diagnostics/system surveillance |
 |
Combi Plus, up to 128 addressable sensors per standard panel size |
|
|
|


Combi has been designed to operate in the full range
of environments from commercial premises through to
heavy
industrial applications which may require hazardous
area sensing.
Typical monitor locations are - public buildings, car
parks, tunnels, breweries, boiler plant rooms, water
treatment works, H&V control, manufacturing, process
plants, horticulture, hotels, offices. |


Each gas sensor continuously monitors the atmosphere, reporting any hazardous conditions to the control unit, for display by the alpha numeric screen indicating the reporting sensor, gas type, concentration and alarm status. Alarm levels that are exceeded will automatically activate a variety of signal outputs including analogue/digital data and user selectable relays.
The Combi system operates on a 4-core (addressable)
or 2/3 core (direct) cable network and has the capacity
to monitor up to 64 addressable and 16 direct sensors
of various gas types. Larger systems offering unlimited
sensors can be achieved using multiple combi units housed
in a 19 rack based system. The Combi is supplied
ready to use with precalibrated gas sensors and provides
for additional sensors that can be easily added to any
point of the network. |


| Sensor
points |
1-64 addressable Can bus and/or
16 direct 4~20mA
Combi Plus - 128 addressable |
| Measurements |
Combustible Gas - L.E.L., % vol
Toxic Gas - ppm, % vol
Oxygen - % vol - Depletion/Enrichment
Refrigerant - ppm
Any 4 ~ 20mA transmitter |
| Indicators -
control unit concentration |
Dot matrix LCD 4 line 40 character - indicating sensor location, gas type, concentration (rising or falling), alarm status, system fault, line fault, sensor fault, inhibit, real time clock, event memory
Red LED - global alarm, Amber LED - global fault, Amber LED-inhibit |
|
|
|