Flow Sample Systems
|
|
GDS301 C553
(Single Line Sample Unit)
|
|
|


|
Measurements |
Combustible Gas L.E.L %Vol, ppm
Toxic Gas - ppm, %Vol
Oxygen - % Vol
|
|
Power Supply |
230/115vAC or 24vDC ± 15%
The two voltages may be used
simultaneously (standby batteries) |
|
Frequency |
50/60Hz |
|
Consumption |
10 watts |
|
Alarm Settings |
Digital setting (fully adjustable
between zero and full scale) |
| Alarm delay |
T1 - 10 seconds, T2 - 30 seconds,
T1 + T2 - 10 minutes |
| Indicators |
Power - Green L.E.D.
Alarms - Low/High - Red L.E.D.
Flow fail - Amber L.E.D.
Fault - Amber L.E.D.
System test alarm L.E.D's flashing |
| Outputs |
Low alarm relay - S.P.C.O
High alarm relay - S.P.C.O
Fault alarm relay - S.P.C.O
Flow fail - S.P.C.O
Relays rated 5A/230vAC
ND or NE pre set normally de energised
Analogue 4-20mA/1-5v
24vDC - 100mA max
(Auxiliary equipment supply) |
|
Audible Alarm
|
Low, High gas and Fault
Permanent mute option |
|
Reset Switch |
Auto or Manual - pre set manual |
|
Test Switch |
Used to check alarm indicators, sounder and relay action |
| Inhibit |
Isolation of alarm relays during service |
| Protection |
IP65 |
| Environmental |
Ambient temperature -5 to 45°C
Storage temperature +10 to 60°C
Humidity range 0 - 90 RH |
| Cable Entry |
Rear, side, top, bottom |
| Sample Tube |
6mm OD 4mm ID
Max. length 100m |
| Exhaust port |
8mm OD |
| Miscellaneous |
Dimensions 315mmW 265mm H 95mm D
Weight 3.8kg
Cable entry - bottom, sides, rear |
|

|
|
|
|