GDS - Gas Detection Systems and Equipment Technologies Ltd
Home GDS Products Services About Us Technical Data Downloads News/Products Contact Us

Fixed Systems
Combi
Gas Net
GDS 404
GDS 2010
GDS 100
GDS 202
GDS 10
Back To Fixed Systems

 

 
 

GDS404
C467b
(1-4 Channel Gas Alarm)


Search


  



Fault Alarm Relay - Common S.P.C.O
Normally energised or de-energised
Channel Relays - 1 per channel high or low selectable S.P.C.O
Normally energised or de-energised, latched or unlatched
General Alarm Relay - resetable S.P.C.O
All contracts rated 5A-230vAC
Analogue 4~20mA output per channel
Output 24vDC @ 100mA max - auxiliary equipment (non inductive)
Audible Alarm Permanent mute option
Lo, Hi, Fault alarms
Alarm Settings Digital Setting (fully adjustable between zero and fullscale)
Delay to alarm T1 - 10 seconds, T2 - 30 seconds, T1 + T2 - 10 minutes
Sensor inputs Bridge type 3 wire mV input
4~20mA (electrochemical/infrared)
Sensor cable 3 core 1.5mm2 screened <1.5km
Miscellaneous EMC approvals EN50270 Marine EN60945
Enclosure - cable entry - bottom/rear
Operating temperature -10 to +50?C
Relative Humidity 0 - 90%
Protection IP52 - option IP65
Dimensions 310W x 265H x 75Dmm
Weight 3.6kg
Optional battery backup
Field terminals - 2.5mm quick release
System/lamp test
Remote Accept/Reset
Alarm isolate during service - inhibit






Sensors



Repeated for each channel 1~4
terminals 14-21


 

GDS Technologies Ltd
Fusion Point, Ash Lane, Garforth,
Leeds UK LS25 2GA
Tel +44 (0)113 286 0166
Fax +44 (0)113 287 8178
Email sales@gds-technologies.co.uk
www.gds-technologies.co.uk
GDS Technologies


This document is not contractual and the equipment specification may be modified at any time without prior notice.