15/30J-win Redline Prime 1 Hydrocarbon
Product Overview
The 15/30J-win Redline Prime 1 Hydrocarbon is a safe area ABS flame retardant detector housing with display, designed to allow quick and easy access to its interior.
Features & Benefits
- Robust and weatherproof
- Flexible output options
- Addressable or stand alone
- Hyper Terminal communications RS232 line data and set up with 232 adapter
Additional Information
PDF Downloads
15/30J-win Redline Prime 1 Hydrocarbon The 15/30J-win Redline Prime 1 Hydrocarbon is a safe area ABS flame retardant detector housing with display, designed to allow quick and easy access to its interior. The detector is robust and weather-proof with improved response times due to the four mounting spacers allowing increased air movement around the detector these spacers also improve the mounting of the unit particularly on circular pillars typically found in carparks.
GENERAL DATA
This information relates to the device operating continuously.
Hydrocarbon Sensor
Operation – continuous diffusion NDIR (duel wave-length)
Measuring Range – Standard 0~100% LEL 0~100% Vol
Others available
Accuracy – ± 5% F.S.D
Warm up time to zero – < 20 seconds
Response time to target gas T90 – < 35 seconds
Long term zero drift ± 5% F.S.D
The 4~20mA output provides a fault indication by reducing the output to below 2mA,
with the recovery from fault condition being automatic.
ELECTRICAL DATA
Input voltage – 3 wire device 18 to 35V DC – 24v DC nominal (polarity protected)
Output – 4~20mA (selectable as sink or source)
Fail signal – 4~20mA reduced to 2mA
Maximum current consumption – 130mA
Maximum loop resistance in source mode – 250R
Resolution – 0.15% of span
Output resolution – 0.02mA
Maximum offset drift – ± 20uA
Relays Optional – Low / high / fault alarms S.P.C.O. 0.5A @30v DC
JUNCTION BOX
Type – 30J Safe area use only
Ingress Protection – IP64
Material – ABS Flame retardent FR40 / Lid Screws M4SS
Finish – Signal White RAL 9003
Weight – 380gms
Entries – Rear 5-20mm knock outs / Sides, Top, Bottom – not specified
Mounting
Standoffs – M4 or No 8 screws
Drill at (C) when standoffs removed
Conduit box – drill at (A) 4.5mm
Surface mount box – drill at (B) 4.5mm
EU Design No. – 01359723-000
Environmental Data – IP64 + Water Shield IP65
Operating Conditions – 0 ~100% RH (non-condensing) / -15 ~ +55ºC
Storage Conditions – 0~99% RH non-condensing / -20 ~ +60ºC
Accessories – Optional
Collector Cone + Universal Fitting
Universal Fitting (test gas applicator/spray deflector)
Flow Block
Duct Mount Kit
Detector Head Weather Shield
Top Accessories
P1 Universal Fitting
P1 Watershield
P1 Collector Cone + Universal Fitting
P1 Flow Block
For a full list of related products available please contact us via email sales@gds-technologies.co.uk