Available Configuration
Combi Gas Detection Range
Product Overview
The Combi range (comprising of Combi 80, 64, 16, Rack, Panel and Din Rail Mount) of multi-channel control systems offers an incredibly versatile approach whilst ensuring a reliable safety system across all industries and applications.
Features & Benefits
- Offering the latest in addressable technology
- Flexible system architecture to meet specific environmental requirements
- Additional user interfaces
- Opportunity to extend system to over 1000 addressable sensors via the Combi CANbus addressable network
Combi Gas Detection Range The Combi range of multi-channel control systems offers an incredibly versatile approach whilst ensuring a reliable safety system across all industries and applications. Having the capacity to monitor up to 64 addressable and 16 direct sensors, 8 of which can be converted to accept mV catalytic sensors. Larger system requirements can also be met with over 1000 addressable sensors possible through a networked Combi solution. Designed to take the user experience to the next level, the Combi can be installed in all customer environments with configurations available as a wall mounted unit, 19’’ rack system, panel and din rail mount. Combi features a vast range of optional equipment including Combi software, enabling full data logging facilities with system management, providing real time views showing sensor locations, alarm status and actual gas values.
Combi 80 | Combi 64 | Combi 16 | Combi Din Rail Mount | Combi Panel Mount | Combi 19″ Rack | |
---|---|---|---|---|---|---|
Sensors | 1-64 addressable 4 wire 16 direct 4~20mA – 3 wire 1~8 optional mV bridge inputs 3 wire |
1-64 addressable 4wire |
16 direct 4~20mA 1~8 optional mV bridge inputs 3 wire |
1-64 addressable 4 wire |
1-64 addressable 4 wire 16 direct 4~20mA – 3 wire 1~8 optional mV bridge inputs 3 wire |
|
Measurements | Combustible Gas – L.E.L, % Vol. Toxic Gas – ppm Oxygen – % Vol. – Depletion / Enrichment Refrigerant – ppm Any 4~20mA Transmitter |
|||||
Sensor Types | Catalytic, Electrochemical, Infrared, PID, Semiconductor | |||||
Control Panels Available | Wall Mount Unit 19’’ Rack System | Wall Mount Unit 19’’ Rack System Panel Mount Din Rail Mount | Wall Mount Unit 19’’ Rack System | Wall Mount Unit 19’’ Rack System Panel Mount Din Rail Mount | Wall Mount Unit 19’’ Rack System | |
Outputs | MODbus 8 User Selectable Relays Optional: 4~20mA / Up to 64 Relays |
|||||
Relays | Global relay S.P.C.O – Inhibit relay S.P.C.O 8 user selectable relays Type: 2 D.P.C.O/6 S.P.C.O rated @ 5A-230v AC Relay Modes: NE/ND Delay |
See options | Global relay S.P.C.O Inhibit relay S.P.C.O |
|||
Power | 230/115v AC or 24v DC ± 15%Control unit 7.5w quiescent 17w full alarm Sensor – 1.25w Internal power supply 20 sensors max |
|||||
Panel Indication | Dot matrix LCD 4 line 40 character-indicates sensor location, gas type, alarm status, system fault, sensor line fault, sensor fault, inhibit, real time clock, event memory Red LED – global alarm Amber LED – global fault Amber LED – inhibit |
|||||
Audible Alarm | Alarm / Fault – Permanent Mute Option 68dB @ 1m | |||||
Digital Communications | RS232 – USB Data Log / Event Log RS485 x 2 – MODbus | |||||
Event Logging | Combi Soft – Full data logging management tool Individual sensor logging – 1-60 min storage readings Data Link – Remote logging | |||||
Operating Temperature | -10°C to +50°C | |||||
Storage Temperature | +5°C to +55°C | |||||
Humidity | 0-95 non condensing | |||||
Ingress Protection | IP52 *IP65 available with over housing* IP54 – Combi Industrial | IP52 | IP50 | IP50 | ||
Dimensions | Standard: 315W x 265H x 95D Combi Industrial Box 1: 386W x 280H x 137D Combi Industrial Box 2: 386W x 500H x 137D |
295W x 120H x 80D | 310W x 115H x 50D | 19’’ x 3U x 300mm | ||
Weight | 5.5KG | 4.5KG | 5.5KG | 1.5KG | 0.7KG | 6KG |
Enclosure | Ash Grey BSA01, Mild Steel Powder Coat | Brushed Aluminium | ||||
Standards | EMC BSEN 50270 Low Voltage BS EN 61010-1 |
Top Accessories CombiSoft (CombiSoftware)
CombiSoft is a data logging system configuration tool that can be used to store readings from a Combi system on an attached Windows based PC. Combi Repeater Panel
The Combi Repeater Panel may be required as a duplicate console sited elsewhere. The Repeater can be connected giving the user an interface identical to the main combi panel. CAN Status Indicator
The CAN Status Indicator may be used as a remote indicator warning panel, providing visual and audible alarms or by menu selection, used as a repeater unit giving details of individual sensor readings and alarms from the selected sensor groups. Combi 32 Way Relay Panel
The Combi 32 Way Relay Panel extends the number of programmable relays on the Combi CAN line system. E-Stops
For a full list of related products available please contact us via email sales@gds-technologies.co.uk XDI-win F1
The XDI-win F1 is an Exd detector with window feature display, housed within our high-grade aluminium alloy casing. Approvals include ATEX and IECEX. XDI-F1
The XDI-F1 is an Exd detector housed within our high-grade aluminium alloy casing. Approvals include ATEX and IECEX. 15/30J-F1
The 15/30J-F1 is a safe area ABS flame retardant detector housing, designed to allow quick and easy access to its interior. Aspirated Sensor Units
Designed with occupational health and safety in mind, the ASU is leading the way in enhancing personnel safety and wellbeing management With the ASU located at 1.5m above floor level, either as a stand-alone unit or as part of a network system, a sample draw line continuously monitors from the target area. 15-30J-F1